Good price  online

products details

Home > Products >
Aquaculture Wastewater Treatment System
>
1-30T/H Aquaculture Wastewater Treatment System Corrosion Resistant Small Footprint

1-30T/H Aquaculture Wastewater Treatment System Corrosion Resistant Small Footprint

Brand Name: aa&ss
Model Number: DHX-CQ/10
MOQ: 1 set
Price: $10,000 to $20,000 per set
Payment Terms: L/C,T/T
Supply Ability: 2 sets/month
Detail Information
Place of Origin:
China
Alias:
Aquaculture Wastewater Treatment System
Parameter:
1-30T/h
Process:
BDD
Material:
Corrosion-resistant
Application:
Removal Of Organics And Ammonia Nitrogen From Wastewater
Customized Service:
Customizable On Demand
Installationtype:
Modular, On-site Assembly
Automationlevel:
Semi-automatic To Fully Automatic Control Systems
Supply Ability:
2 sets/month
Highlight:

30T/H Aquaculture Wastewater Treatment System

,

Wastewater Treatment System Corrosion Resistant

,

Small Footprint Wastewater Treatment System

Product Description

10 t/d EO electrochemical wastewater treatment equipment, applicable to: treatment of breeding wastewater from livestock and poultry breeding, aquaculture and special breeding

Quick Details

Aquaculture wastewater treatment equipment

AC 200~400V WIDE VOLTAGE INPUT OPTIONAL

Equipment power 3.5-170 kW optional

Pollutant Removal Rate:50-100%

Aquaculture wastewater can all be treated

Operation without adding any chemical agents

The equipment only uses electricity

Skid-mounted equipment

Small footprint

Ready-to-use, flexible operation time based on wastewater quality

Unattended, fully automatic operation, simple maintenance

Customizable on demand

Aquaculture wastewater is a major pollutant generated by the livestock and poultry breeding industry, characterized by high concentrations of organic matter, high ammonia nitrogen, high suspended solids, and abundant pathogenic microorganisms. The wastewater contains large amounts of undigested feed, feces, animal hair, and disinfectant residues, leading to extremely high concentrations of chemical oxygen demand (COD), biochemical oxygen demand (BOD), ammonia nitrogen, and total phosphorus. It also exhibits significant fluctuations in water quality and is prone to decomposition and odor. Improper treatment and direct discharge can cause water eutrophication, disease transmission, and pose serious threats to the surrounding water environment and public health. Although the traditional combined process of "solid-liquid separation + anaerobic/aerobic biological treatment" is widely used, it often faces challenges such as long treatment cycles, large footprint, high surplus sludge production, limited removal of ammonia nitrogen and refractory organic matter, and unstable system operation during winter low temperatures or water quality shocks.

Addressing the core treatment difficulties of aquaculture wastewater—"high load, high ammonia nitrogen, and susceptibility to pathogen proliferation"—the CQDHX SERIES EO Electrochemical Oxidation Equipment, developed and manufactured by our company (AA&SS AQUA HITECH CO., LTD.), generates highly oxidizing reactive species through electrochemical action. This not only effectively decomposes residual organic matter and some refractory nitrogenous compounds in the wastewater but also directly kills or inactivates pathogenic microorganisms (such as E. coli, parasite eggs). Its significant advantages lie in its operation without the addition of any chemical agents, avoiding the potential harmful disinfection by-products from additional dosing of disinfectants (e.g., chlorine-based agents) and the chemical sludge issues from coagulant addition. Furthermore, the equipment does not generate any chemical residual solid waste, making the treatment process clean and particularly suitable as a safety assurance unit for advanced treatment and reuse of aquaculture wastewater.

Wastewater undergoes pretreatment, including screening to remove large particulate matter and efficient solid-liquid separation (such as screw pressing, centrifugation, or screening) to remove the vast majority of suspended solids and fibrous materials. The pretreated liquid enters an equalization tank for homogenization, then proceeds to the front-end EC Electrochemical Equipment. This efficiently removes residual fine suspended solids, colloidal substances, part of the dissolved organic matter, and phosphates. It can also assist in removing some color and odor through reduction reactions, effectively reducing the load for subsequent treatment.

The supernatant after treatment and solid-liquid separation primarily contains dissolved organic pollutants, ammonia nitrogen, and potential pathogens. The wastewater then enters the CQDHX SERIES EO Electrochemical Oxidation Equipment. The electrochemical oxidation process can directly attack and degrade part of the organic pollutants. More importantly, it achieves highly efficient and rapid disinfection through generated active chlorine species, thoroughly eliminating the biological safety hazards of the wastewater. Our company's equipment is optimized for the characteristics of aquaculture wastewater, ensuring stable and efficient generation of reactive species even when treating water with high organic background levels, thereby achieving pollutant reduction and water safety.

The effluent treated by the CQDHX SERIES EO Electrochemical Oxidation Equipment can meet standards for discharge or resource reuse (such as agricultural irrigation, livestock pen flushing).

The CQDHX SERIES EO Electrochemical Oxidation Equipment, independently developed by our company, simultaneously achieves deep oxidation of organic matter and efficient inactivation of pathogens in a clean operation mode without chemical addition. This not only significantly improves effluent quality and safety but also simplifies operational management, providing a technical pathway for aquaculture wastewater treatment and resource recovery that features a small footprint, high efficiency, and no risk of secondary pollution.

For wastewater with special characteristics or unique treatment objectives, our company's engineers provide technical support and solutions.

Technical specifications for 10 tons/day wastewater treatment capacity

Equipment Model

DHX-CQ/10

Electrode Model

CQ-350-10-3

Number of Electrodes

5 sets

Input Voltage

AC200-400V

Power Supply Efficiency

85%

Frequency Range

50-60Hz

Operating Voltage

DC3-15V

Operating Current

1000-1375A

Operating Time

0.1-24h/day

Operating Temperature

1-80

Influent COD

1000-15000mg/L

COD Removal Rate

50-100%

Pipe Connection Size

DN50

Equipment Net Weight

700kg

Equipment Dimensions

3x2x1.7m

Precautions:

  1. The equipment must be installed in a well-ventilated, rain-sheltered, non-explosion-proof area.
  2. The equipment power supply uses a three-phase five-wire system, and the equipment must be reliably grounded.
  3. Do not strike the electrodes with hard objects.

Application Scope:

Water flushing manure wastewater, soaking pit manure wastewater, dry scraping manure wastewater, etc.

1-30T/H Aquaculture Wastewater Treatment System Corrosion Resistant Small Footprint 0

Main pollutants in aquaculture wastewater: manure, feed residue, urine, etc.

1-30T/H Aquaculture Wastewater Treatment System Corrosion Resistant Small Footprint 1

Time
h

COD
mg/L

COD Removal Rate

0

3145

0.00%

0.5

2107

33.00%

1

1204

61.72%

1.5

662

78.95%

2

130

95.87%

2.5

39.13

98.76%

1-30T/H Aquaculture Wastewater Treatment System Corrosion Resistant Small Footprint 2

Main pollutants in aquaculture wastewater: manure, feed residue, urine, etc.

1-30T/H Aquaculture Wastewater Treatment System Corrosion Resistant Small Footprint 3

Time
h

COD
mg/L

COD Removal Rate

0

10980

0.00%

1

4966

54.77%

2

2408

78.07%

2.5

602

94.52%

3

451

95.89%

3.5

301

97.26%

1-30T/H Aquaculture Wastewater Treatment System Corrosion Resistant Small Footprint 4

Aquaculture Wastewater Treatment Process

Process 1

 

Aquaculture wastewater

Water Quality Equalization & EC Electrochemical System
(Grid, Screening, removes most suspended solids, fibers, and colloids)

CQDHX SERIES EO Electrochemical Oxidation Equipment
(Removes organic matter and ammonia nitrogen, degrades residual antibiotics, thoroughly inactivates pathogens)

Emission

 

Process 2

 

Aquaculture wastewater

Water Quality Equalization & EC Electrochemical System
(Grid, Screening, removes most suspended solids, fibers, and colloids)

Pretreatment System (Optional)

(Improves the treatment efficiency of the electrochemical system)

CQDHX SERIES EO Electrochemical Oxidation Equipment
(Removes organic matter and ammonia nitrogen, degrades residual antibiotics, thoroughly inactivates pathogens)

Emission

Treatment Capacity of Electrochemical Oxidation Wastewater Treatment Equipment

Unit Wastewater Treatment Capacity

Primary Pollutants

Pollutant Removal Rate

0.5-30T/h

Organic matter

50-100%

Ammonia nitrogen

30-99%

Color

50-95%

Suspended Solids

90-99%

E. coli

90-99%